Error Code nP
No power / power supply issue - electric dryer power cord not connected or house power supply incorrect
Moderate
Address soon - your appliance may not work properly
Also displayed as: nP
How to Fix
- 1
Check outlet voltage — should be 110–125 VAC at L1/L2.
- 2
If outlet voltage is out of range, check house fuse or circuit breaker.
- 3
Measure voltage between connector BK or WH (Black Wire) at controller and BL2 (White Wire) — should be 110–125 VAC.
- 4
If voltage is present at outlet but not at controller, check if power cord is properly connected.
- 5
Verify controller wire is not disconnected and terminal block connection is secure.
- 6
Confirm that power cord neutral (N) line connects to center terminal (N) on terminal block.
- 7
If all connections are correct and power is present, replace the controller.