Error Code tE2
Thermistor of blower housing — outlet thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Same diagnostic procedure as tE1.
- 2
Disconnect harness from thermistor assembly connector.
- 3
Measure resistance and compare to temperature-resistance table.
- 4
Replace thermistor if out of range.
- 5
Replace controller if thermistor is in range and connector checks pass.