Error Code PS
Power supply wire connection error
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
PS means 'Power Supply'.
- 2
Check that power cord N (Neutral/White) wire is connected to center terminal block screw.
- 3
Check that Red and Black wires are connected to left and right terminal block screws.
- 4
Verify connection between BK-2 (Black Wire) linked to controller and BL2-1 (White Wire) is 110-125V. If NO: check power cord connection.
- 5
Check outlet voltage is 110-125VAC. If NO: check fuse or circuit breaker.
- 6
If 4-wire connection: ensure Green ground wire goes to external ground screw and neutral ground wire is moved to center screw.
Other Error Codes for DLEX4200W
Thermistor of steam generator open or shorted
Power failure — circuit breaker tripped or power outage occurred
No power / power cord not connected correctly
Water supply pump error
Door switch abnormal
Ductwork approximately 80% blocked — flow sense restriction warning
Ductwork approximately 95% blocked — critical flow sense restriction
NFC module open or shorted