Error Code nP
No power detected
Moderate
Address soon - your appliance may not work properly
Also displayed as: nP
How to Fix
- 1
Check that dryer is plugged in and outlet has 110–125VAC.
- 2
Measure voltage between connectors BK2 or WH2 (Black Wire) and BL2 (White Wire) linked to controller; should be 110–125VAC.
- 3
If no voltage, check power cord connection.
- 4
If voltage is present but display remains off, check controller wire for disconnection and reconnect controller.
- 5
Verify power cord N (Neutral) line matches terminal center N line.
- 6
If all connections are correct and display remains off, replace the controller (main PCB).
Other Error Codes for DLEX4370W
Power failure or incorrect power supply
NFC module wrong or unresponsive
Ductwork approximately 75% blocked
Ductwork approximately 90% blocked
Outlet thermistor open or shorted (second thermistor)
Power supply wire connection wrong or loose (electric dryer)
NFC module open or shorted
Ductwork approximately 80% blocked