Error Code dE
Door switch abnormal
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
How to Fix
- 1
Enter diagnostic test mode.
- 2
Press START/PAUSE once to start tumbling without heat.
- 3
Open the door — dE should display and chime should sound 7 times and drum light should illuminate (if equipped).
- 4
If dE does not display or drum light does not come on, proceed to mechanical test.
- 5
Disconnect WH1 and BL3 connectors from main PCB.
- 6
Measure resistance between NA6 pin (GN) and chassis ground screw — should be less than 1 Ω.
- 7
If resistance is not less than 1 Ω, check all wiring harness connections and ground screws.
- 8
If ground is good, disconnect BL2 and WH4 connectors from main PCB.
- 9
Measure resistance between BL2 (WH wire) and WH4 (YL wire) — should be less than 1 Ω with door closed and infinite (open) with door open.
- 10
If resistance values are reversed or incorrect, replace the door switch.
- 11
If resistance values are correct, replace the main PCB.
- 12
For drum light circuit: disconnect WH4 and black tab relay connectors from main PCB. Measure resistance between WH4 YL and WH4 BK — should be less than 1 Ω with door open and infinite with door closed.
- 13
If drum light circuit fails, replace light bulb first, then light socket if bulb replacement does not resolve.
Other Error Codes for DLG3601B
NFC module type is wrong
EE PROM (non-volatile memory) operation is abnormal
NFC module open or shorted
Exhaust ductwork approximately 95%+ blocked - FlowSense alert
Water supply pump failure - pump AD value below 10 in test mode
Exhaust ductwork approximately 90-95% blocked - FlowSense alert
Thermistor of steam generator - open or shorted
No power / power supply issue - electric dryer power cord not connected or house power supply incorrect