Error Code gAS
Gas supply or gas service turned off
Moderate
Address soon - your appliance may not work properly
Also displayed as: gAS
How to Fix
- 1
Confirm that the house gas shutoff valve is fully open.
- 2
Confirm that the dryer gas shutoff valve (installed within 6 ft of dryer) is fully open.
- 3
Check that gas supply line is connected and not kinked or damaged.
- 4
Turn off gas, disconnect supply hose, and verify no blockage in gas inlet.
- 5
Perform gas leak check at all connections using a non-corrosive leak detection fluid after restoring gas.
- 6
If gas supply is confirmed adequate and dryer still shows gAS, check gas valve coil resistances (Valve 1 and Valve 2: each 1.5 kΩ–2.5 kΩ) and replace gas valve if out of range.
- 7
Check igniter resistance (50–800 Ω); replace if open circuit.
- 8
Check flame detector (open at 370°F max, close at 320°F, closed resistance less than 1 Ω); replace if faulty.
- 9
Check hi-limit thermostat (open at 203±4°F, close at 158±4°F) and safety thermostat (open at 230±4°F, manual reset); replace faulty thermostats.