Error Code PF
Power failure - house fuse blown or circuit breaker tripped, or power outage occurred
Moderate
Address soon - your appliance may not work properly
Also displayed as: PF
How to Fix
- 1
Check house fuse or circuit breaker and reset breaker or replace fuse.
- 2
Do not increase fuse capacity beyond rated amperage.
- 3
If the problem is a circuit overload, have it corrected by a qualified electrician.
- 4
Verify outlet voltage is 208–240 VAC ±10% for electric dryer.
- 5
Check power cord connection at terminal block for proper wiring (white neutral to center, red and black to outer terminals).
Other Error Codes for DLG3601B
NFC module type is wrong
EE PROM (non-volatile memory) operation is abnormal
NFC module open or shorted
Exhaust ductwork approximately 95%+ blocked - FlowSense alert
Water supply pump failure - pump AD value below 10 in test mode
Exhaust ductwork approximately 90-95% blocked - FlowSense alert
Thermistor of steam generator - open or shorted
No power / power supply issue - electric dryer power cord not connected or house power supply incorrect