Error Code PS
Power supply wire connection error
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
PS means 'Power Supply'.
- 2
Check that power cord N (Neutral/White) wire is connected to center terminal block screw.
- 3
Check that Red and Black wires are connected to left and right terminal block screws.
- 4
Verify connection between BK-2 (Black Wire) linked to controller and BL2-1 (White Wire) is 110-125V. If NO: check power cord connection.
- 5
Check outlet voltage is 110-125VAC. If NO: check fuse or circuit breaker.
- 6
If 4-wire connection: ensure Green ground wire goes to external ground screw and neutral ground wire is moved to center screw.
Other Error Codes for DLG3601W
Ductwork approximately 80% blocked — flow sense restriction warning
Ductwork approximately 95% blocked — critical flow sense restriction
NFC module open or shorted
Big load indicator for steam cycle load size selection (not a fault code)
Humidity sensor failure
Door switch abnormal
Thermistor of steam generator open or shorted
Power failure — circuit breaker tripped or power outage occurred