Error Code gAS
Gas supply or service turned off
Moderate
Address soon - your appliance may not work properly
Also displayed as: gAS
How to Fix
- 1
Confirm that house gas shutoff and the dryer gas shutoff are both fully open.
- 2
Verify gas supply pressure is adequate.
- 3
Check that gas service is active to the dwelling.
- 4
If gas is on and pressure is correct, check gas valve coil resistances (each coil should be 1.5k-2.5kΩ).
- 5
Check igniter resistance (50-800Ω for part 5318EL3001).
- 6
Check flame detector: open at 370°F max (resistance = infinity), close at 320°F (resistance <1Ω).