Error Code HE

Your dryer isn't heating properly or is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HE

What This Means

Restricted vent system causing excessive heat buildup; Thermistor failure or out of range; Heater malfunction; Thermostat failure; Airflow blockage

What actually causes this:

Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.

First Thing to Check

Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.

Parts Involved

ThermistorThermostat 1Thermostat 2Thermostat 3Heater AssemblyExhaust Vent

How to Fix

  1. 1

    1. Check exhaust vent system for restrictions or blockages

  2. 2

    2. Measure thermistor resistance: Cycling Thermistor 1 should be 10KOhm at 25C, Cycling Thermistor 2 should be 238.231KOhm at 25C

  3. 3

    3. Check thermostat resistance: all thermostats should be < 1Ohm (infinity means replace)

  4. 4

    4. Check heater resistance: DUAL heater — 13Ohm (PIN 2-3), 34Ohm (PIN 1-2). SINGLE heater — 10Ohm (PIN 1-3)

  5. 5

    5. If resistance is infinity on heater, replace heater assembly

  6. 6

    6. Call customer service if issue persists

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

Need more help with your Samsung DV50K7500G?