Error Code HC

Your dryer isn't heating properly or is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC

What This Means

Thermistor resistance out of range; Main PCB malfunction; Restricted vent system causing excessive heat buildup; Heater malfunction; Thermostat failure

What actually causes this:

Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.

First Thing to Check

Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.

Parts Involved

ThermistorMain PCBThermostat 1Thermostat 2Thermostat 3Heater Assembly

How to Fix

  1. 1

    1. Check the PCB and thermistor connections

  2. 2

    2. Measure thermistor resistance: should be 10K ohm at 25 degrees C (77 degrees F)

  3. 3

    3. Check thermostat resistance: should be < 1 ohm (infinity means replace)

  4. 4

    4. Check heater resistance: SINGLE heater 10 ohm (PIN 1-3); DUAL heater 13 ohm (PIN 2-3) and 34 ohm (PIN 1-2)

  5. 5

    5. Check exhaust vent system for restrictions or blockages

  6. 6

    6. If resistance is infinity on heater, replace heater assembly

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

Need more help with your Samsung DVE45T3200?