Error Code tC5

A secondary temperature sensor is giving bad readings

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC5

What This Means

Clogged lint screen restricting airflow; Restricted vent system causing heat buildup; Thermistor 2 resistance out of range (open or shorted)

What actually causes this:

Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.

First Thing to Check

Clean the lint screen thoroughly and make sure the exhaust vent path is clear.

Parts Involved

Thermistor 2 (Temperature Sensor)Lint Screen

How to Fix

  1. 1

    1. Check for a clogged lint screen

  2. 2

    2. Check if the vent system is restricted

  3. 3

    3. Check the thermistor 2 resistance

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

Need more help with your Samsung DVE50R8500W?