From the service manual for Samsung DV45B6300 Series Dryers (2021)

From the service manual

Good to know

3 technician insights for the Samsung DV45B6300 Series Dryers (2021)

Gas Model Ignition Troubleshooting

Gas models

Gas valve solenoid coils have temperature-dependent resistance — they test normal when cold but fail after 5-10 minutes of heat If igniter glows white-hot but gas does not flow, the coils are the problem 95% of the time — replace the coil kit, not the valve body Always replace coils as a set (2 or 3 depending on valve type) even if only one tests bad — they age together After coil replacement, run 3 consecutive heat cycles to verify — some failures only manifest after thermal cycling

Seeing an error code on your display? Look up your error code → for more specific diagnostic information.