Error Code C9
Your dryer vent is over 90% blocked — needs immediate cleaning
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C9 or C90
What This Means
Exhaust duct severely obstructed with lint or debris; Exhaust duct crushed or kinked; Outside exhaust hood damper fully stuck closed
What actually causes this:
Severe lint buildup in the exhaust vent is almost completely blocking airflow. This is a fire hazard.
First Thing to Check
Stop using the dryer and check the exhaust vent immediately for heavy lint buildup.
Parts Involved
How to Fix
- 1
1. Run the Vent Blockage Test via Smart Install (Time + Start/Pause for 7 seconds)
- 2
2. Thoroughly inspect and clean or replace the entire exhaust duct run
- 3
3. Check for crushed or kinked ductwork
- 4
4. Ensure the outside exhaust hood damper opens freely
- 5
5. Retest after cleaning