Error Code HC

Your dryer isn't heating properly or is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC

What This Means

Restricted vent system causing excessive heat buildup; Thermistor resistance out of range; Heater malfunction; Motor malfunction; Thermostat failure

What actually causes this:

Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.

First Thing to Check

Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.

Parts Involved

ThermistorThermostat 1Thermostat 2Thermostat 3Heater AssemblyMain PBA

How to Fix

  1. 1

    1. Check the PCB and thermistor

  2. 2

    2. Check exhaust vent system for restrictions or blockages

  3. 3

    3. Measure thermistor resistance: should be 10K Ohm at 25 degrees C (77 degrees F)

  4. 4

    4. Check thermostat resistance: should be < 1 Ohm (infinity means replace)

  5. 5

    5. Check heater resistance: DUAL heater -- 13 Ohm between PIN 2-3, 34 Ohm between PIN 1-2; SINGLE heater -- 10 Ohm between PIN 1-3

  6. 6

    6. If resistance is infinity on heater, replace heater assembly

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

Need more help with your Samsung DVG50BG8300E?