No heat
Parts commonly needed when your Samsung dryer has this issue. Recommendations are based on repair patterns and may not diagnose your specific problem.
Verified Components
Parts
3Part numbers confirmed across multiple retailers for DVG60M9900V
Repair tips for this issue
From the service manual for Samsung DVE60A9900 Series Dryers
From the service manual
Good to know
5 technician insights for the Samsung DVE60A9900 Series Dryers
After service — run Time Dry 20 minutes and check for HE/HC error
After completing any service work, operate Time Dry for 20 minutes and check whether HE/HC error occurs. If HC error occurs, specifically check the terminal wiring of the compressor. This may indicate a desorption phenomenon of the pin for the wiring of the compressor. This is a required post-service verification step.
Dual dryer unit — upper and lower are separate systems
This is a dual-unit dryer with an upper delicate dryer and a lower tumble dryer. They have separate heating elements (540W upper vs 5300W lower), separate thermistors with very different resistance values (238.23KΩ upper vs 10KΩ lower), and separate cycle sets. When diagnosing issues, always determine which unit (upper or lower) is affected before testing components. The tC code relates to thermistor 1 (lower) while tC5 relates to thermistor 2 (upper).
Gas valve coil resistances — four separate coils to test
Gas modelsThe gas valve assembly (25M01A) has four separate solenoid coils, each with different resistance values: pins 1-2 = 1365Ω, pins 1-3 = 560Ω, pins 4-5 = 1325Ω, pins 6-7 = 1000Ω. Any coil reading infinity means the valve must be replaced. Always shut off gas supply before testing.
Seeing an error code on your display? Look up your error code → for more specific diagnostic information.