Error Code AE
The dryer's internal parts aren't communicating properly
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: AE
What This Means
Faulty Main PCB; Faulty Display PCB; Damaged or loose wire harness between Main PCB and Display PCB
What actually causes this:
A loose wire connection between the control board and display, or a power surge scrambled the electronics.
First Thing to Check
Unplug the dryer for 2 minutes, then plug it back in — this resets the electronics.
Parts Involved
How to Fix
- 1
1. Check wire harness connection between Main PCB and Display PCB for loose or damaged connectors
- 2
2. Inspect wire harness for pinched, cut, or corroded wires
- 3
3. Check PCB and wire harness
- 4
4. If wiring is intact, replace PCB
Other Error Codes for DVG60M9900W
The dryer thinks the door is open while running
The dryer's memory chip has a communication error
A button on the control panel is stuck or shorted
The door switch isn't working properly
Your dryer's temperature sensor isn't reading correctly
Your dryer is getting the wrong type of electrical power
Your dryer isn't heating properly or is overheating
Your dryer is getting the wrong voltage from the outlet