Dryers: Shuts off unexpectedly
Parts frequently associated with this issue and repair guidance from service manuals.
Parts commonly needed for this issue
Based on repair data across Samsung and LG dryer models. These parts are frequently associated with this problem — they may not be the cause of your specific issue.
Lint Filter
OEM: DC61-05489A
Verified across 4 retailers
Control Panel
OEM: DC97-21616D
Verified across 3 retailers
Touch Pad
OEM: DC90-27479J
Verified across 3 retailers
Touch Pad
OEM: DC97-18553A
Verified across 3 retailers
Control Panel
OEM: DC97-17990A
Verified across 2 retailers
Control Panel
OEM: DC97-18284A
Verified across 2 retailers
Control Panel
OEM: DC97-18285A
Verified across 2 retailers
Touch Pad
OEM: DC90-27484A
Verified across 2 retailers
Control Panel
OEM: DC97-21616A
Verified across 2 retailers
Control Panel
OEM: DC97-17990C
Verified across 2 retailers
Control Panel
OEM: DC97-21616C
Verified across 2 retailers
Control Panel
OEM: DC97-18106D
Verified across 2 retailers
Repair tips for this issue
From manufacturer service manuals.
From the service manual
Good to know
6 technician insights for the this appliance
Gas igniter -- extremely fragile component
Gas modelsThe hot surface igniter (101D) is explicitly called out as fragile in the manual. When removing the burner assembly, use extreme care to avoid damage to the igniter. Resistance should be 40-400 ohm. Do not touch the ceramic element with bare hands as oils can cause premature failure. The manual uses a special warning symbol for this component.
Live voltage on PCB -- electric shock risk
Electric modelsAC220-240V is applied to the triac T1 and T2 on the main PCB. Even when the dryer appears off, dangerous voltage may be present on the PCB. Strong and weak electricity are mixed together on the board. Never touch PCB components while the dryer is plugged in.
Powder coat drum -- special cleaning required
This model uses a Powder Coat (Gray) drum, not stainless steel. When cleaning the drum interior, use a damp cloth with a mild, non-abrasive cleaner suitable for easily marred surfaces. Do not use abrasive substances. Some dye transfer stains may be visible but will not affect subsequent loads. Tumble old towels to remove remaining cleaning substances.
Two different thermistor values -- Electric vs Gas model
Electric modelsThe electric model uses a 10K ohm thermistor at 25 deg C, while the gas model uses a 238.23K ohm thermistor at 25 deg C. These are dramatically different values. When diagnosing tC errors, use the correct reference value for the model type. Additionally, the gas model has a radiant sensor with < 1 ohm resistance that is separate from the thermistor.