Error Code E5
Water supply pump failure - pump valve AD value below 10 in test mode
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
How to Fix
- 1
Activate diagnostic test mode.
- 2
Press START/PAUSE button 4 times.
- 3
Check AD value displayed - if lower than 10, E5 error will display.
- 4
Check connection between harness wire and connector.
- 5
If AD value is still below 10, replace the DC pump.
- 6
Note: Let dryer start each test step before continuing to next; rapid pressing can damage main board.
This Error Applies To
LG DLEX3900W Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
EE PROM operation abnormal
Installation test mode active (duct/exhaust check)
Humidity sensor failure
Power failure - house fuse blown or circuit breaker tripped
No power / power supply incorrect
Ductwork approximately 80% blocked
Ductwork approximately 95% blocked - severe restriction