No power / power supply incorrect
Moderate
Address soon - your appliance may not work properly
Also displayed as: nP
What This Means
Neutral wire disconnected at terminal block; Incorrect wiring at terminal block
How to Fix
- 1
Verify 120VAC between L1 and Neutral.
- 2
Verify 120VAC between L2 and Neutral.
- 3
Correct terminal block wiring.
This Error Applies To
LG DLEX3900W Series Dryers
Service manual exact match: DLEX3900WService manual exact match: DLEX3900BService manual exact match: DLGX3901VService manual exact match: DLEX3700WService manual exact match: DLEX3700BService manual exact match: DLGX3701VService manual exact match: DLEX3900VService manual exact match: DLGX3901W+2 more