Error Code tE1
Thermistor of blower housing - Outlet thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Turn off the dryer and unplug from power.
- 2
Locate the NA6 connector on the main PCB and disconnect it.
- 3
Short pin 4 (Yellow Wire) and pin 5 (Blue Wire) with a metal wire or jumper at the connector end going to the thermistor.
- 4
Restore power and recheck: if tE1 clears, verify wiring connections between the controller and the thermistor connector are properly seated.
- 5
If tE1 persists after shorting, replace the main PCB controller.
- 6
If tE1 does not clear when shorted but the short is confirmed good, disconnect power, separate the thermistor harness connector, and measure resistance across thermistor terminals.
- 7
Compare measured resistance to Thermistor Table 1: 50°F(10°C)=18.0 kΩ, 60°F(16°C)=14.2 kΩ, 70°F(27°C)=9.3 kΩ, 80°F(21°C)=11.7 kΩ, 90°F(32°C)=7.7 kΩ, 100°F(38°C)=6.2 kΩ, 110°F(43°C)=5.2 kΩ, 120°F(49°C)=4.3 kΩ, 130°F(54°C)=2.9 kΩ, 140°F(60°C)=3.0 kΩ, 150°F(66°C)=2.5 kΩ, 160°F(71°C)=2.2 kΩ.
- 8
If resistance is out of range for ambient temperature, replace the thermistor.
- 9
If resistance is in range, check the harness-linking connector for damage, corrosion, or loose pins.
This Error Applies To
LG DLEX4200B Series Dryers
Related Error Codes
NFC module type is wrong
EE PROM (non-volatile memory) operation is abnormal
NFC module open or shorted
Exhaust ductwork approximately 95%+ blocked - FlowSense alert
Water supply pump failure - pump AD value below 10 in test mode
Exhaust ductwork approximately 90-95% blocked - FlowSense alert
Thermistor of steam generator - open or shorted
No power / power supply issue - electric dryer power cord not connected or house power supply incorrect