Error Code HS
Humidity sensor failure
Moderate
Address soon - your appliance may not work properly
Also displayed as: HS
How to Fix
- 1
Turn off the dryer.
- 2
Call for service.
- 3
Technician: inspect moisture sensor bars in lint filter housing for corrosion, damage, or debris.
- 4
Disconnect NA6 connector from main PCB; measure resistance between NA6-(GN) pin and chassis ground — should be less than 1 Ω.
- 5
If greater than 1 Ω: check wiring harness connections and ground screws.
- 6
Place jumper between NA6-(OR) and NA6-(BL); measure resistance between moisture sensor bars inside drum — should be less than 1 Ω.
- 7
Check all sensor harness connectors for corrosion, loose or bent pins, and broken wires.
- 8
If wiring is intact and sensor bars are clean but fault persists: replace main PCB.
This Error Applies To
LG DLEX4270V Series Dryers
Related Error Codes
Power supply wiring error — electric dryer power cord connected incorrectly
FlowSense — exhaust duct approximately 95% blocked
NFC module open or shorted
Steam generator thermistor open or shorted
Power failure — house fuse blown, circuit breaker tripped, or power outage
Water supply pump current is less than threshold (pump fault)
FlowSense — exhaust duct approximately 80% blocked
Outlet thermistor open or shorted (blower housing thermistor #2)