Error Code d90
FlowSense — exhaust duct approximately 90% blocked
Moderate
Address soon - your appliance may not work properly
Also displayed as: d90
How to Fix
- 1
Do not use the dryer until the exhaust system is cleaned and/or repaired.
- 2
Inspect entire duct run for blockage, lint buildup, or crushed sections.
- 3
Check vent hood at exterior — clear obstructions and lint.
- 4
Ensure outside vent shows strong airflow when dryer operates.
- 5
If exhaust run is extremely long, have it rerouted.
- 6
Keep the area around the dryer free of clutter.
- 7
After cleaning, run installation exhaust test: hold SIGNAL ON/OFF and TEMP CONTROL, then press POWER, then START/PAUSE.