Error Code tE2
Outlet thermistor open or shorted (blower housing thermistor #2)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Turn off the dryer.
- 2
Enter diagnostic test mode to confirm tE2.
- 3
Unplug dryer and discharge voltage.
- 4
Disconnect the NA6 connector from the main PCB.
- 5
Measure resistance between NA6-1 (YL) and NA6-4 (BL).
- 6
Compare to thermistor resistance table (same values as tE1 procedure).
- 7
If reading at PCB matches table: replace main PCB.
- 8
If reading does not match: disconnect harness from thermistor connector and measure at thermistor terminals directly.
- 9
If thermistor is out of spec: replace thermistor.
- 10
If thermistor is in spec: check and reseat harness connector between thermistor and PCB.