Error Code dE
Door switch abnormal (only displayed in test mode)
Moderate
Address soon - your appliance may not work properly
What This Means
Door switch is abnormal; Door not fully closed
How to Fix
- 1
Error only displayed in TEST MODE
- 2
Perform door switch test (Test 5)
- 3
Measure resistance at BL2 and BK2/WH1 connectors
- 4
Door closed: resistance between BL2-pin1 (White) and BK2-pin2 (Black) should be below 2500 ohms
- 5
Door open: resistance between BL2-pin1 and BK2-pin2 should be 300-60 ohms
- 6
If out of range, check lamp and door switch
- 7
Replace door switch if faulty
This Error Applies To
LG DLEX7600KE Series Dryers (2016) (2016–present)
Related Error Codes
Thermistor of blower housing open or shorted
Thermistor of steam generator open or shorted
Humidity Sensor failure
Power Failure
EEPROM error — only displayed in test mode
Ductwork approximately 90-95% blocked (displayed for 2 hours only)
Ductwork approximately 95% blocked (displayed for 2 hours only)
Pump error (steam models)