Error Code Add
Steam feeder water supply error — steam generator not filled within 60 seconds
Moderate
Address soon - your appliance may not work properly
Also displayed as: Add
How to Fix
- 1
1. Check steam feeder drawer: Make sure steam feeder is filled with water to MAX line.
- 2
2. Make sure steam feeder is seated properly and drawer is fully closed.
- 3
3. Turn the dryer off then restart the steam cycle.
- 4
4. Do not use distilled water — the water level sensor in steam generator will not work with distilled water.
- 5
5. If pump not working → Unplug dryer and call for service.
- 6
6. If Add displays during drying cycle but water is at MAX → Pump not working; replace pump.
- 7
7. Check CN7 connector wiring for pump (pins 1-2).
This Error Applies To
LG DLEX8900V Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
Power failure / power supply error
Ductwork approximately 90% blocked — exhaust severely restricted
Water supply pump error — pump AD value less than 10 in test mode
Power supply problem
Ductwork approximately 95% blocked — exhaust critically restricted
Outlet thermistor open or shorted (Thermistor of blower housing)
EEPROM / PCB memory error