Error Code F-2
Shorted Sensor Error
Moderate
Address soon - your appliance may not work properly
Also displayed as: F-2
How to Fix
- 1
Unplug the unit.
- 2
Check if the sensor connector is disconnected or loose — check sensor connection and CN10 of Main PCB. If loose, reconnect; if harness is defective, replace or fix.
- 3
Measure resistance of thermistor at pins 5 and 6 of CN6 of Main PCB. Normal = approximately 1.09 kΩ at 25°C (77°F). If abnormal (shorted = near 0Ω), replace the defective thermistor.
- 4
If thermistor resistance is normal, plug in the unit and enter test mode (press any button with Mode knob in Off, then press '4' and '6' simultaneously for 1 second, then press '4' and '6' simultaneously for 1 second again). Check current temp display — normal thermistor value at room temp is 70°F to 90°F.
- 5
If thermistor value is normal in test mode, replace the Relay PCB. If problem persists after Relay PCB replacement, replace the Main PCB.
This Error Applies To
LG LSEL6335 Series Ovens & Ranges