LG Refrigerators

Error Code E CO

Communication Error — Main MICOM to Display MICOM

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    1. Check all connector hinge connections between Main PCB and Display PCB for loose wiring.

  2. 2

    2. Measure voltage at CON101 Pin 18 to Pin 16. Expected: 12 V. If voltage is absent, check hinge connection; if hinge is OK, replace Main PCB.

  3. 3

    3. Measure voltage at CON101 Pin 10 to Pin 16. Expected: 5 V. If absent, check hinge connection; if hinge OK, replace Main PCB.

  4. 4

    4. Measure voltage at CON101 Pin 14 to Pin 16. Expected: Not 0 V or 5 V (should be varying). If stuck at 0 or 5 V, replace Display PCB.

  5. 5

    5. Measure voltage at CON101 Pin 12 to Pin 16. Expected: Not 0 V or 5 V. If stuck at 0 or 5 V, replace Main PCB.

  6. 6

    6. Measure voltage at CON5 Pin 4 to Pin 3. Expected: Not 0 V or 5 V (varying). If stuck, replace Display PCB.

  7. 7

    7. Measure voltage at CON5 Pin 5 to Pin 3. Expected: Not 0 V or 5 V (varying). If stuck, replace Main PCB.

  8. 8

    8. If all voltage checks pass, explain to customer (intermittent communication issue).