Error Code E Sd
Sub PCB Communication Error — Main MICOM to Sub MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
1. Check loose connections between Main PCB (CON3) and Sub PCB (CON1).
- 2
2. Measure voltage at Sub CON1 Pin 8 to Pin 33. Expected: Not 0 V or 5 V (varying). If stuck at 0 or 5 V, check sub PCB connection or replace Sub PCB.
- 3
3. Measure voltage at Sub CON1 Pin 10 to Pin 33. Expected: Not 0 V or 5 V. If stuck, replace Sub PCB.
- 4
4. Measure voltage at Main CON3 Pin 1 to Pin 15. Expected: Not 0 V or 5 V. If stuck, check Display PCB loose connection or replace Display PCB.
- 5
5. Measure voltage at Main CON3 Pin 3 to Pin 15. Expected: Not 0 V or 5 V. If stuck, check Display PCB loose connection or replace Display PCB.
- 6
6. If all voltage checks pass, explain to customer (intermittent Sub PCB communication).
This Error Applies To
LG LCFC26XSS Series Refrigerators