Error Code E CS
Convertible (Pantry) Room Sensor Error
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check for a loose or disconnected connector between Main PCB and convertible room sensor (CON8 pins 18–17). If disconnected, reconnect or repair.
- 2
With power off, measure resistance at CON8 pins 18–17. If 0 Ω (short), replace the convertible sensor.
- 3
With power off, measure resistance at CON8 pins 18–17. If infinite (open), go to step 6.
- 4
Compare resistance against the temperature/resistance table. If out of spec, replace the sensor.
- 5
If resistance is correct, the sensor is functioning normally — explain to customer.
- 6
Check the physical sensor connection. If connection is normal, replace the refrigerator. If connection is abnormal, reconnect or repair.
This Error Applies To
LG LF29H8330 Series Refrigerators