LG Refrigerators

Error Code E CL

Low-side cycle leakage (sealed system)

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Verify error using SVC App Step 1 to determine if sealed system or compressor issue. Check evaporator temperature.

  2. 2

    Check PCB voltage outputs; if abnormal, replace PCB.

  3. 3

    Measure pressures and equalization time after power off. If equalization takes more than 15 minutes, restriction is confirmed.

  4. 4

    If equalization pressure is above 20 psi, compressor is defective. Replace compressor.

  5. 5

    If equalization pressure is 20 psi or below, refrigerant has leaked. Begin with low-pressure side leak inspection (evaporator, suction pipe) using bubble test or leak detector.

  6. 6

    If low-side leak found, replace leaking part plus compressor and drier (moisture contamination).

  7. 7

    If no low-side leak found, inspect high-pressure side (condenser, drier, compressor discharge).

  8. 8

    If high-side leak found, replace the part and drier.

  9. 9

    If no leak found, install UV drier; inspect at next visit with UV light.

  10. 10

    Error code clears automatically when freezer temperature reaches 14°F or below after repair.

This Error Applies To

LG LL31H6530S Series Refrigerators

Service manual exact match: LL31H6530S