Error Code E CO

Communication error between Main MICOM and Display MICOM

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Check all harness connections between main PCB and display PCB for looseness, especially hinge wiring.

  2. 2

    Check voltage at CON101 pins 18–16; expected 12V. If not 12V, check hinge wiring (loose connection). If hinge is OK but voltage is wrong, replace Main PCB.

  3. 3

    Check voltage at CON101 pins 10–16; expected 5V. If not 5V, check hinge connection. If hinge OK, replace Main PCB.

  4. 4

    Check voltage at CON101 pins 14–16; expected 0V or 5V (not between). If not correct, replace Display PCB.

  5. 5

    Check voltage at CON101 pins 12–16; expected 0V or 5V. If not correct, replace Main PCB.

  6. 6

    Check voltage at CON5 pins 4–3; expected 0V or 5V. If not correct, replace Display PCB.

  7. 7

    Check voltage at CON5 pins 5–3; expected 0V or 5V. If not correct, replace Main PCB.

  8. 8

    If all checks are within spec, explain to customer.