LG Refrigerators2017–present
Error Code gF E
Flow Meter / Water Flow Error
Moderate
Address soon - your appliance may not work properly
Also displayed as: gF E
What This Means
No water input; Low water pressure; Defective flow meter connection
How to Fix
- 1
Check that water supply is connected and saddle valve is fully open.
- 2
Verify water pressure is between 20-120 psi.
- 3
Check flow meter connector between Main PCB and sensor.
- 4
Measure flow meter resistance (Red wire to Black wire should be 4-30 kΩ).
- 5
Replace flow meter if resistance is out of range.
- 6
Replace Main PCB if flow meter is good but error persists.
This Error Applies To
LG LMXS28626S Series Refrigerators (2017) (2017–present)
Service manual exact match: LMXS28626SService manual exact match: LMXS28626DService manual exact match: LMXS28626WService manual exact match: LMXS28626BService manual exact match: LFXS28566SService manual exact match: LFXS28566DService manual exact match: LFXS28566WService manual exact match: LFXS28566B+2 more