LG Refrigerators2017–present

Error Code gF E

Flow Meter / Water Flow Error

Moderate

Address soon - your appliance may not work properly

Also displayed as: gF E

What This Means

No water input; Low water pressure; Defective flow meter connection

How to Fix

  1. 1

    Check that water supply is connected and saddle valve is fully open.

  2. 2

    Verify water pressure is between 20-120 psi.

  3. 3

    Check flow meter connector between Main PCB and sensor.

  4. 4

    Measure flow meter resistance (Red wire to Black wire should be 4-30 kΩ).

  5. 5

    Replace flow meter if resistance is out of range.

  6. 6

    Replace Main PCB if flow meter is good but error persists.

This Error Applies To

LG LMXS28626S Series Refrigerators (2017) (2017–present)

Service manual exact match: LMXS28626SService manual exact match: LMXS28626DService manual exact match: LMXS28626WService manual exact match: LMXS28626BService manual exact match: LFXS28566SService manual exact match: LFXS28566DService manual exact match: LFXS28566WService manual exact match: LFXS28566B+2 more