Error Code E CO
Communication Error between Main PCB MICOM and Display MICOM
Moderate
Address soon - your appliance may not work properly
What This Means
Loose connection at CON101 (display PCB connector); Faulty hinge wire harness (loose connection through hinge); Failed display PCB; Failed main PCB; Poor transmitter/receiver (Tx/Rx) circuit
How to Fix
- 1
Check for loose connection at CON101 on display PCB
- 2
Check voltage between Red to White/Red wires at CON101: 12V = go to step 3; other = check hinge for loose connection or change Main PCB
- 3
Check voltage between White/Red to Orange at CON101: 0V or 5V = change Display PCB; other = go to step 4
- 4
Check voltage between White/Red to White/Black at CON101: 0V or 5V = change Main PCB; other = go to step 5
- 5
Check for loose connection at CON5 on Main PCB; check voltage between Orange to Red/White: 0V or 5V = change Display PCB; other = go to step 6
- 6
Check voltage between White/Red to White/Black at CON5 on Main PCB: 0V or 5V = change Main PCB; other = explain to customer
This Error Applies To
LG LRDCS2603S Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Fan Error (BLDC Fan Motor for Freezer)
Refrigerator Sensor Error
Icing Sensor Error (Ice Maker sensor)
Freezer Defrost Sensor Error
Freezer Sensor Error
Freezer Defrost Heater Error — defrost sensor has not reached 41F/5C within 80 minutes of defrost start
Low Side Cycle Leakage (refrigerant leak or sealed system restriction on low side)
Room Temperature Sensor Error