LG Refrigerators2020–present

Error Code E CO

Communication Error between Main PCB MICOM and Display MICOM

Moderate

Address soon - your appliance may not work properly

What This Means

Loose connection at CON101 (display PCB connector); Faulty hinge wire harness (loose connection through hinge); Failed display PCB; Failed main PCB; Poor transmitter/receiver (Tx/Rx) circuit

How to Fix

  1. 1

    Check for loose connection at CON101 on display PCB

  2. 2

    Check voltage between Red to White/Red wires at CON101: 12V = go to step 3; other = check hinge for loose connection or change Main PCB

  3. 3

    Check voltage between White/Red to Orange at CON101: 0V or 5V = change Display PCB; other = go to step 4

  4. 4

    Check voltage between White/Red to White/Black at CON101: 0V or 5V = change Main PCB; other = go to step 5

  5. 5

    Check for loose connection at CON5 on Main PCB; check voltage between Orange to Red/White: 0V or 5V = change Display PCB; other = go to step 6

  6. 6

    Check voltage between White/Red to White/Black at CON5 on Main PCB: 0V or 5V = change Main PCB; other = explain to customer

This Error Applies To

LG LRDCS2603S Series Refrigerators (2020) (2020–present)

Service manual exact match: LRDCS2603S/01Service manual exact match: LRDCS2603S