LG Refrigerators
Error Code CF E
Condenser Fan Error
Moderate
Address soon - your appliance may not work properly
Also displayed as: CF E
How to Fix
- 1
Reset unit and enter Test Mode 1 (push test button 1 time).
- 2
Measure condenser fan motor supply voltage at CON3 pins 4–1: expected 12V. If not 12V, replace Main PCB.
- 3
Check if condenser fan visibly rotates — if not, proceed.
- 4
Measure fan control signal voltage at CON3 pins 3–1: expected 0V < voltage < 5V. If not in range, replace Main PCB.
- 5
Measure fan feedback voltage at CON3 pins 3–1: expected 0V < voltage < 5V. If not in range, replace condenser fan motor.
- 6
Manually spin condenser fan — if sticky, replace condenser fan motor.
- 7
If all voltages and rotation are correct: explain to customer.
This Error Applies To
LG LRFS28XB Series Refrigerators
Service manual exact match: LRFS28XBD/00Service manual exact match: LRFS28XBS/00Service manual exact match: LRFS28XBM/01