Error Code dH F
Poor Defrosting / Defrost Heater Error
Moderate
Address soon - your appliance may not work properly
Also displayed as: dH F
How to Fix
- 1
Check door gasket for damage — if gasket is damaged, replace door gasket.
- 2
Check Fuse-M resistance (CON7 pins 6–12): expected 0Ω (continuity). If open/∞, replace defrost heater assembly.
- 3
Check defrost heater resistance (CON7 pins 6–12): expected 34–42Ω. If open, replace heater.
- 4
Check defrost sensor resistance at CON5 pins 10–9: expected ~22kΩ at room temperature. If OL/∞, replace defrost sensor.
- 5
Enter Test Mode 3 (push test button 3 times, display shows '33 33'): measure voltage at CON7 pins 6–12 — expected 112–116V. If voltage is present and heater does not heat, replace defrost heater.
- 6
Enter Test Mode 1: measure CON7 pins 6–12 — expected 0V at rest. If not 0V, replace Main PCB.
- 7
If all components test good and error persists: explain to customer.
This Error Applies To
LG LRFS28XB Series Refrigerators