Error Code E CO
Communication error between main MICOM and display MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check loose connections at display PCB connectors and hinge wiring connections.
- 2
Reconnect any loose connectors.
- 3
Measure voltage at CON101 18th Pin ~ 16th Pin. Should be 12V. If not 12V: check hinge connection (loose) or replace Main PCB.
- 4
Measure voltage at CON101 10th Pin ~ 16th Pin. Should be 5V. If not 5V: check hinge connection or replace Main PCB.
- 5
Measure voltage at CON101 14th Pin ~ 16th Pin. Should be not 0 or 5V. If 0 or 5V: replace Display PCB.
- 6
Measure voltage at CON101 12th Pin ~ 16th Pin. Should be not 0 or 5V. If 0 or 5V: replace Main PCB.
- 7
Measure voltage at CON5 4th Pin ~ 3rd Pin. Should be not 0 or 5V. If 0 or 5V: replace Display PCB.
- 8
Measure voltage at CON5 5th Pin ~ 3rd Pin. Should be not 0 or 5V. If 0 or 5V: replace Main PCB.
- 9
If all pass: explain to customer.
This Error Applies To
LG LRFXC2606S Series Refrigerators