LG Refrigerators
Error Code E IF
Defect of BLDC fan motor for ice making (icing fan)
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Reset the unit. Enter Test Mode 1 (push test button 1 time).
- 2
Measure fan motor voltage at CON4 pins 12th~11th. Should be 11.4~12.6V.
- 3
If voltage is NOT 11.4~12.6V: replace Main PCB.
- 4
If voltage is correct: check airflow in icing compartment. If windy: go to step 5.
- 5
If not windy: rotate icing fan by hand. If sticky/seized: replace fan motor.
- 6
Step 5 - Check fan feedback voltage at CON4 pins 10th~11th. Should be not 0 or 5V. If 0 or 5V: replace the icing fan motor.
- 7
Step 6 - Check PWM voltage at CON4 pins 9th~11th. Should be not 0 or 5V. If 0 or 5V: replace Main PCB.
- 8
If all pass: explain to customer.
This Error Applies To
LG LRFXC2606S Series Refrigerators
Service manual exact match: LRFXC2606S