Error Code F dH
Freezer Defrost Heater Error — Freezer failed to defrost within 80 minutes
Moderate
Address soon - your appliance may not work properly
Also displayed as: dH F
How to Fix
- 1
Check door gasket for damage. If door gasket is damaged, replace the door gasket.
- 2
Check Defrost control part (Fuse-M). Measure heater resistance at CON9 pins 5-13. Expected: 42~500 ohm. If out of range, change Fuse-M.
- 3
Check Defrost Sensor resistance at CON9 pins 5-13. Nominal 22k ohm at room temp or OFF indicates defective sensor — replace sensor.
- 4
Enter Test Mode 3 (push test button 3 times, display shows 33 33). Measure heater voltage at CON9 pins 5-13. Expected: 112V~116V. If voltage is not present, check input voltage supply and replace Main PCB if input is OK.
- 5
Enter Test Mode 1 (push test button 1 time). Measure heater voltage at CON9 pins 5-13. Expected: 0V. If voltage is not 0V, replace Main PCB.
This Error Applies To
LG LRMDS3006D Series Refrigerators
Related Error Codes
Freezer Sensor Error
Refrigerator Defrost Sensor Error
Refrigerator Defrost Heater Error — Refrigerator failed to defrost within 80 minutes
Freezer Fan Motor Error
Refrigerator Sensor Error
Icing Sensor Error (Ice Compartment Sensor or Ice Maker Sensor)
Freezer Defrost Sensor Error
Refrigerator (Fresh Food) Fan Motor Error