Error Code PE
Pressure Sensor Error
Moderate
Address soon - your appliance may not work properly
What This Means
Pressure sensor assembly out of order; Water level frequency consistently below 10 kHz or over 30 kHz; Connector to pressure sensor disconnected or disassembled; Pressure sensor resistance out of range (pin 1 to pin 3: 21-23 Ω ±10%); Air chamber and tube clogged
How to Fix
- 1
Confirm PE is displayed — note: PE error does not auto-clear; if not resolved within 20 seconds, power will turn off and error will blink
- 2
Check if connector to pressure sensor is disconnected — if yes, reconnect or repair
- 3
Check resistance of pressure sensor (pin 1 to pin 3) — should be 21-23 Ω ±10%; if out of range, replace pressure switch
- 4
Check if air chamber and tube are clogged — if yes, fix air chamber and remove foreign material
- 5
If all above pass, replace MAIN PWB assembly
This Error Applies To
LG WM3670H Series Washers (2016) (2016–present)