Error Code LE
Locked Motor Error
Moderate
Address soon - your appliance may not work properly
What This Means
Motor harness connector (3-pin, male, white) not connected to stator assembly connector (3-pin, female, white); Bad or unstable electrical contact at 4-pin motor harness connector and 4-pin Main PWB female connector; Motor harness between stator assembly and Main PWB cut (open circuit); Rotor magnet cracked; Stator winding resistance out of range (not 5–15 Ω between U-V, V-W, W-V)
How to Fix
- 1
Confirm LE is displayed
- 2
Check motor drive connector at Main PWB assembly (GY3) — reconnect if disconnected
- 3
Check motor harness wiring connector — reconnect if disconnected
- 4
Inspect rotor magnet for cracks — replace rotor if cracked
- 5
Pull out GY3 connector (Grey 3P, male); measure resistance U-V, V-W, W-U — should be 5–15 Ω each
- 6
If resistance out of range: replace stator
- 7
If resistance in range: check IPM in controller
- 8
If IPM check fails: replace Main PWB assembly
This Error Applies To
LG WM4000H Series Washers (2023) (2023–present)