LG Washers2022–present

Error Code Ed4

Open Circuit Softener Pump

Moderate

Address soon - your appliance may not work properly

What This Means

Amount of fabric softener in reservoir did not decrease; Open circuit in softener pump wiring

How to Fix

  1. 1

    Confirm connector is well connected — if not, reconnect

  2. 2

    Verify wire is intact — if cut, replace Sub PCB

  3. 3

    If both are good, replace module harness and min harness

This Error Applies To

LG WM5500H Series Washers (2022) (2022–present)

Service manual exact match: WM5500HBAService manual exact match: WM5500H*AService manual exact match: WM5500HVAService manual exact match: WM5500HWA