Error Code PE
Pressure Sensor Error — pressure sensor assembly out of order; water level frequency consistently below 10 kHz or over 30 kHz
Moderate
Address soon - your appliance may not work properly
What This Means
Pressure sensor connector broken or loose; Pressure sensor resistance out of range (pin 1 to pin 3 should be 21-23 Ohm ±10%); Air chamber and tube clogged; MAIN PWB Assembly defective
How to Fix
- 1
Confirm PE error is displayed.
- 2
Check pressure sensor connector for damage or looseness — reconnect or repair.
- 3
Measure resistance of pressure sensor from pin 1 to pin 3 (should be 21-23 Ohm ±10%). If out of range, replace pressure switch.
- 4
Check if air chamber and tube are clogged — fix and remove foreign material.
- 5
If all above pass, replace MAIN PWB Assembly.
This Error Applies To
LG WM9000H Series Washers (2015) (2015–present)
Related Error Codes
Water Inlet Error
EEPROM Error — EEPROM is out of order
Power Failure — power supply interrupted while washing machine was working
WiFi Error — WiFi modem self-check function error
Door Open Error (variant) — door lock switch assembly failure
Overflow Error — water is overflowing; water level frequency is over 21.3 kHz
Door Open Error — door not fully closed or door switch fault
Locked Motor Error