Error Code OE
Drain Error - machine unable to drain water within expected time
Moderate
Address soon - your appliance may not work properly
Also displayed as: OE
What This Means
Drain pump connector disconnected or harness damaged; Drain hose kinked, clogged, frozen, or positioned too low; Air chamber or pressure tube clogged (water level frequency below 26.0 kHz in service mode); Drain pump coil resistance out of range (should be 10-20 Ohm); Voltage at pump not 120V +/- 5% during run; Failed Main PCBA
How to Fix
- 1
If connector to pump motor assembly is disconnected: Reconnect or repair the connector
- 2
Enter SVC Mode and press Start/Pause 9 times to activate Pump Check — verify pump runs
- 3
If pump coil resistance is out of range (not 10-20 Ohm): Replace the drain pump assembly
- 4
If voltage at WH6 Pin 1 is out of range when pump should run: Replace Main PCB Assembly
- 5
Ensure drain hose end is 39 inches (99 cm) above floor
- 6
Do not insert drain hose more than 12 inches (30 cm) into standpipe
- 7
Replace harness if wiring is damaged
- 8
Replace pump if all electrical checks pass
This Error Applies To
LG WT5680H Series Washers (2013) (2013–present)
Related Error Codes
Unbalance Error - load detected as unevenly distributed during spin
Over Flow Error - water level too high, overfill condition detected
Locked Motor Error - motor cannot rotate, hall sensor or motor fault
Door Lock Error - lid lock mechanism failing to lock
Motor Locked by Foreign Object - object caught between wash plate and inner basket
Door/Lid Error - lid lock not detecting closed and locked position
Thermistor Error - temperature sensor open or short circuit
Pressure Sensor Error - water level sensor malfunction