Samsung Dishwashers2023–present

Error Code AC6

The motor controller board stopped responding to the main computer

Moderate

Address soon - your appliance may not work properly

Also displayed as: No display, changes to pause

What This Means

Main PBA or Inverter PBA is out of order; Communications connection for the Main PBA or Inverter PBA not properly connected

What actually causes this:

The circuit board that controls the wash and drain motors has lost its connection or failed

First Thing to Check

Turn off the dishwasher at the circuit breaker, wait 2 minutes, then turn it back on

Parts Involved

Inverter PBAMain PBA

How to Fix

  1. 1

    1. Check connector between Main PBA and Inverter PBA — reconnect

  2. 2

    2. Check CN901 and CN902 connectors for BLDC Pump and BLDC Drain on Main PBA

  3. 3

    3. If connections are good, replace Inverter PBA

  4. 4

    4. If still failing, replace Main PBA

This Error Applies To

Samsung DW80B7070A Series Dishwashers (2023) (2023–present)

Service manual exact match: DW80BB707012AAService manual exact match: DW80B7070US/AAService manual exact match: DW80B7070UG/AAService manual exact match: DW80B7071US/AAService manual exact match: DW80B7071UG/AAService manual exact match: DW80B6060US/AAService manual exact match: DW80B6060UG/AAService manual exact match: DW80B7070AP/AC+2 more