Samsung Dishwashers2020–present

Error Code AC

The dishwasher's control boards can't talk to each other

Moderate

Address soon - your appliance may not work properly

Also displayed as: AC (no display during operation)

What This Means

Main PBA or Sub PBA is out of order; Communications connection for the Main PBA or Sub PBA is not properly connected; Wire harness damaged

What actually causes this:

A power surge or loose wire connection disrupted communication between the control boards

First Thing to Check

Turn off the dishwasher at the circuit breaker, wait 60 seconds, then turn it back on

Parts Involved

Main PBASub PBAWire Harness

How to Fix

  1. 1

    1. Check connector between Main PBA and Sub PBA — reconnect

  2. 2

    2. Check all wire harness connections between boards

  3. 3

    3. If error persists after reconnecting all connectors, replace Sub PBA

  4. 4

    4. If error still persists, replace Main PBA

This Error Applies To

Samsung DW80K5050U Series Dishwashers (2020) (2020–present)

Service manual exact match: DW80K5050US/ACService manual exact match: DW80K5050UG/AAService manual exact match: DW80K5050UB/ACService manual exact match: DW80K5050UW/AC