Samsung Dryers2014–present

Error Code HC

Your dryer isn't heating properly or is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC

What This Means

Thermistor malfunction; PCB malfunction; Restricted vent system causing excessive heat buildup; Heater element failure

What actually causes this:

Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.

First Thing to Check

Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.

Parts Involved

ThermistorMain PCBHeater AssemblyExhaust Vent

How to Fix

  1. 1

    1. Check the PCB and thermistor connections

  2. 2

    2. Measure thermistor resistance: should be 10KΩ at 25°C (77°F)

  3. 3

    3. Check exhaust vent system for restrictions or blockages

  4. 4

    4. Check heater resistance: SINGLE heater — 9.2-9.6Ω between PIN 1-3

  5. 5

    5. If resistance is infinity on heater, replace heater assembly

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DV40J3000E Series Dryers (2014) (2014–present)

Service manual exact match: DV40J3000EW/A2Service manual exact match: DV400EWHDWR/AAService manual exact match: DV40J3000GW/A2Service manual exact match: DV400GWHDWR/AAService manual exact match: DV40J3000GWService manual exact match: DV40J3000EW

Need more help with your Samsung dryers?