Samsung Dryers

Error Code tC5

A secondary temperature sensor is giving bad readings

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC5

What This Means

Clogged lint screen restricting airflow; Restricted vent system causing abnormal temperatures; Thermistor 2 resistance out of range (open or shorted)

What actually causes this:

Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.

First Thing to Check

Clean the lint screen thoroughly and make sure the exhaust vent path is clear.

Parts Involved

Thermistor 2Lint Screen

How to Fix

  1. 1

    1. Check and clean the lint screen

  2. 2

    2. Inspect the exhaust vent system for restrictions or blockages

  3. 3

    3. Measure thermistor 2 resistance

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

This Error Applies To

Samsung DV50R5 Series Dryers

Service manual exact match: DVG50R5400V/A3Service manual exact match: DVE50R5200W/A3Service manual exact match: DVE50R5400V/A3Service manual exact match: DVG50R5400W/A3Service manual exact match: DVE50R5400W/A3Service manual exact match: DVG50R5200W/A3