Samsung Dryers2024–present

Error Code tC

Your dryer's temperature sensor isn't reading correctly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC

What This Means

Clogged lint screen restricting airflow and causing abnormal temperature readings; Restricted vent system causing heat buildup affecting thermistor readings; Thermistor resistance out of range (open or shorted); Disconnected or damaged thermistor wiring harness

What actually causes this:

Usually a clogged lint screen or blocked exhaust vent — restricted airflow causes the sensor to misread temperatures.

First Thing to Check

Pull out the lint screen and clean off all the lint, then check that your exhaust vent hose isn't kinked or blocked.

Parts Involved

Thermistor (Cycling Thermistor)Lint ScreenExhaust Vent

How to Fix

  1. 1

    1. Check and clean the lint screen

  2. 2

    2. Inspect the exhaust vent system for restrictions or blockages

  3. 3

    3. Disconnect harness and test cycling thermistor: Blue wire Pin 3 to Red wire Pin 6

  4. 4

    4. Measure thermistor resistance: should be approximately 10K ohms at 25 degrees C (77 degrees F)

  5. 5

    5. If thermistor resistance is out of range (open or significantly deviated), replace the thermistor

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DV52M7750 Series Dryers (2024) (2024–present)

Service manual exact match: DVE52M7750W/A3Service manual exact match: DVE52M7750V/A3Service manual exact match: DVE52M7750P/ACService manual exact match: DVG52M7750W/A3Service manual exact match: DVG52M7750V/A3Service manual exact match: DVE52M7750VService manual exact match: DVE52M7750PService manual exact match: DVG52M7750W+2 more